OUTPUTS


Each of the 4 outputs has a group containing related settings and information. Replace the letter x with the channel number from 1 to 4.


Ox0

Mode

Enable / disable the output. A disabled output does not produce events and can not be controlled.

0 = disabled / 1 = enabled - Default: enabled

Ox1

Name

Set a meaningful name representing the associated function.

4 ... 15 alphanumeric characters - Default: out1 ... out4

THE FOLLOWING PARAMETERS ARE NOT AUTOMATICALLY UPDATED IN THE CLOUD ACCOUNT (KEPT AS LOCAL) IF THE NAME STARTS WITH A POINT

INTENTIONAL PUBLICATION IS POSSIBLE WITH THE AT # SMAP COMMAND

Ox2

Status

Current status of the output.

0 means open, deactivated, off / 1 means closed, activated, on.

0 / 1

Ox3

Remaining time

By activating an output it is possible to specify a time or a date for its deactivation. This is the time remaining to shutdown or the release date:

 0000...3600 if formatted with 4 digits is expressed in seconds

 012035 if formatted as six digits is expressed in hhmmss

 2106171230 if formatted with 10 digits it is a date YYMMDDhhmm

If the on-board clock has never been set, the device will only count hours and minutes, ignoring the date.

Ox4

Color

This optional parameter defines the color to be used by web platform to show the output channel.

red / green / yellow / blue - Default: green