OUTPUTS Each of the 4 outputs has a group containing related settings and information. Replace the letter x with the channel number from 1 to 4. |
|
|
Ox0 |
Mode Enable / disable the output. A disabled output does not produce events and can not be controlled. 0 = disabled / 1 = enabled - Default: enabled |
|
Ox1 |
Name Set a meaningful name representing the associated function. 4 ... 15 alphanumeric characters - Default: out1 ... out4 |
|
THE FOLLOWING PARAMETERS ARE NOT AUTOMATICALLY UPDATED IN THE CLOUD ACCOUNT (KEPT AS LOCAL) IF THE NAME STARTS WITH A POINT INTENTIONAL PUBLICATION IS POSSIBLE WITH THE AT # SMAP COMMAND |
|
|
Ox2 |
Status Current status of the output. 0 means open, deactivated, off / 1 means closed, activated, on. 0 / 1 |
|
Ox3 |
Remaining time By activating an output it is possible to specify a time or a date for its deactivation. This is the time remaining to shutdown or the release date: 0000...3600 if formatted with 4 digits is expressed in seconds 012035 if formatted as six digits is expressed in hhmmss 2106171230 if formatted with 10 digits it is a date YYMMDDhhmm If the on-board clock has never been set, the device will only count hours and minutes, ignoring the date. |
|
Ox4 |
Color This optional parameter defines the color to be used by web platform to show the output channel. red / green / yellow / blue - Default: green |