Status

Messages ››
Parent Previous Next

Status SMS, issued on request or as trailing part of alert message, returns the status of local enabled resources.

Multiple SMSs will be used when the status messages exceed the max allowable length.

When all the resources are enabled, the content is something like that:



IDENTIFIER

>

Mobi.Control




DIGITAL INPUT I1

>

I1: 0

DIGITAL INPUT I2

>

I2: 1

DIGITAL INPUT I3

>

I3: 1

DIGITAL INPUT I4

>

I4: 0

DIGITAL INPUT I5

>

I5: 1

DIGITAL INPUT I6

>

I6: 1

DIGITAL INPUT I7

>

I7: 0

DIGITAL INPUT I8

>

I8: 1

DIGITAL INPUT C1

>

C1: 0

DIGITAL INPUT C2

>

C2: 1

TIMER COUNTER INPUT T1

>

T1: 350 min

TIMER COUNTER INPUT T2

>

T2: 12 min

PULSE COUNTER INPUT P1

>

P1: 11560 W - 12 W/min

PULSE COUNTER INPUT P2

>

P2: 4381 mc - 22 mc/min

ANALOG INPUT 1

>

A1: 48.65 V

ANALOG INPUT 2

>

A2: -14 C




SETPOINT 1

>

S1: 50

SETPOINT 2 (+SAFE 2)

>

S2: 20 4




OUTPUT 1

>

O1: on 13/09/2013 18:30

OUTPUT 2

>

O2: on 00:00:09

POWER SUPPLY

>

main: OK

BATTERY

>

batt: 80%

TEMPERATURE

>

temp: 23 C

CALL

>

call: pulse

USERS GROUP 1 ENABLE

>

usr1: on

USERD GROUP 2 ENABLE

>

usr2: off




IDENTIFIER


Short text reporting the identifier assigned to Mobi.Control (Settings Device):

Mobi.Control



DIGITAL INPUT I1 ... I8


Status of digital inputs:

0 : input is open, inactive

1 : input is closed, active



DIGITAL INPUT C1 ... C2


Status of additional digital inputs:

0 : input is open, inactive

1 : input is closed, active



TIME COUNTER INPUT T1 ... T2

Accumulated time (input closed, active) followed by min (minutes):

350 min



PULSE COUNTER INPUT P1 ... P2

Accumulated counts followed by measuring unit, current ratio (measured during last minute) followed by measuring unit / min:

11560 W - 12 W/min



ANALOG INPUT A1 ... A2

Returns current reading (mean over 4 sec) followed by measuring unit:

48.65 V

Temperature measured by external sensor is reported when the channel has been set as NTC.

Value and measuring unit according to channel setting [°C / °F].

-14 °C



SETPOINT S1 ... S2


Current setpoint (used to control outputs based on analog input measurement).

Nothing is returned when setpoint=0 (disabled).

The safety limit value may follow (not returned when set to zero).

20 4

typical ambient temperature regulation, setpoint=20 antifrost=4 (assuming input channel has been set to °C)



OUTPUTS O1 ... O2


Status of outputs:

off: output is released, inactive

on : output is active

remaining time may follow when output has been activated using timer option (9 minutes remaining)

on 00:00:09

release date may follow when output has been activated with expiration date (will be turned off April 25, 2013 at noon).

on 25/04/13,12:00:00

remaining time and symbol | will follow when the output has been activated by clip command (activated by clip, will be released within 15 seconds).

on +15 |



POWER SUPPLY


Status of the main power supply:

OK: main power supply detected

KO: main power supply missing



BATTERY

Battery level indicator:

100%

when the battery is not connected reports full charge (100%)



TEMPERATURE

Temperature measured by internal sensor, returned in °C:

23 °C



CALL

Information about remote free call command (CLIP), operating mode:

none

pulse

toggle

reverse

dtmf



USR1 ... 2

Status of users belonging to group 1 or 2:

on

incoming calls and shortcut commands accepted

off

incoming calls and shortcut commands rejected



Service can be enabled / disabled using commands

(Start / Stop) from remote, scheduled or event