H016 ... H017 TIME COUNTER INPUTS |
Settings related to time counter inputs T1 and T2 (T2 not available for Mobi.Key) |
DEFAULT REVERT The whole group tO DEFAULT FACTORY SETTINGS |
DELETE REMOVE all settings for current entry |
|||
QRCODE SHOW SMS AND QRCODE TO BE SENT TO REMOTE DEVICE TO APPLY NEW SETTINGS |
CONFIRM CONFIRM NEW SETTINGS FOR CURRENT ENTRY |
ENABLE / DISABLE
Disabling the channel all related events will not take place.
Status message includes only the enabled channels.
NAME
Assign a meaningful name, to better identify the application.
Up to 20 characters available.
ACTIVATION TIME
Minimum duration time to start / stop the time count.
Range 1 second to 17 hours 59 minutes 59 seconds, Default 3 seconds.
ACCUMULATED TIME THRESHOLD
The event will be triggered when the accumulated time exceeds the threshold. Reaching 999999 minutes restart from zero.
Range 0 ... 999999 minutes, default=0 (disabled).
Select SELF RESET to set accumulated time counter to zero when threshold is reached.
Select the optional local sound to be played.
TEXT
The text to be used for the internal logger, local and remote tracing.